This test is used to determine the product's suitability for storage, transportation, and use in high-temperature climate conditions. The severity of the test depends on the temperature of the high temperature and the duration of the exposure.
Test Standard Reference: GB/T 2423.2, IEC 60068-2-2, IEIA 364, MIL-STD-810F
Common test parameters: +55°C+ -2°C, duration 4H (minimum)
Low temperature test:
The purpose of the cryogenic test is to determine the suitability of military and civilian equipment for storage and operation at low temperatures.
Reference standards: IEC 60068-2-1 (GB/T2423.1), EIA634, MIL-STD-810F
Common test parameters: -10°C+-3°C, duration 4H (minimum)
Simulated severe cold area use: -40°C, duration 4H (minimum)
Test items | Guideline | Common test parameters |
Temperature and humidity test | IEC 60068-2-78(GB/T 2423.3), | 40°C, 93%RH, Duration: 12H (least) |
Rapid temperature change test | IEC 60068-2-38(GB/T 2423.34),GJB150.5... | -10°C to 65°C, 24H cycles 10 times |
High temperature test | IEC 60068-2-2(GB/T 2423.2),EIA 364, | +55°C+-2°C, duration: 4H (minimum) |
Low temperature test | IEC 60068-2-1(GB/T 2423.1), | -10°C+-3°C, duration: 4H (minimum) |